In pharmaceutical distribution, monitoring conditions is more than keeping an eye on them. With the measurement history, the distributor shows that medicines have been kept in the right conditions, so it is worth thinking ahead about what happens when a measuring device fails. We explain what the EU guidelines on good distribution practice say about measurement and how two independent measurements prepare for a device failure.
Measurement is evidence
In Finland, Fimea's regulation 1/2019 requires distributors of authorised or registered medicinal products for human use to follow the EU guidelines on good distribution practice (GDP guidelines, 2013/C 343/01). The section of the guidelines is given in brackets.
According to the guidelines, warehousing operations must ensure that appropriate storage conditions are maintained (5.5). If requested, customers should be provided with information to demonstrate that products have complied with the temperature storage conditions (9.4). On transport, the guidelines say that it should be possible to demonstrate that the medicines have not been exposed to conditions that may compromise their quality and integrity (9.1).
Conditions are shown with the measurement history. If there is a gap in the temperature curve, conditions during the gap are hard to show with measurements.
What the guidelines say about measurement
- Factors to be considered. Suitable equipment and procedures should be in place to check the environment where medicinal products are stored. The factors to be considered include temperature, light, humidity and cleanliness of the premises (3.2.1).
- Temperature mapping. An initial temperature mapping exercise should be carried out on the storage area before use, under representative conditions. Based on it, temperature monitoring equipment should be positioned in the areas that experience the extremes of fluctuations. The mapping should be repeated according to a risk assessment or whenever significant modifications are made to the facility or the temperature controlling equipment (3.2.1).
- Alarms. Appropriate alarm systems should be in place to provide alerts when there are excursions from pre-defined storage conditions, and alarms should be regularly tested (3.3).
- Calibration and records. Equipment used to monitor the environment should be calibrated at defined intervals based on a risk and reliability assessment, traceable to a national or international measurement standard. The guidelines name thermo hygrometers as key equipment, for which records of repair, maintenance and calibration should be kept (3.3).
- Keeping data. Back up data should be retained for at least five years at a separate and secure location (3.3.1). Documents should also be retained for at least five years (4.2).
- Preparing for failure. Procedures to be followed if the system fails or breaks down should be defined, and they should include systems for the restoration of data (3.3.1).
When the only measuring device fails
A measuring device can fail, its battery can run out or its data transfer can break. If a space has only one measurement, there may be no data from the time of the failure, and the conditions may not be possible to show afterwards with measurements.
The guidelines do not use the word redundancy and do not require two measurements. They say that procedures for failures should be defined. Two independent measurements in the same space can be part of them: when one device fails, the other keeps measuring. Restoring data from backups is a procedure of its own.
Two independent measurements in practice
Cold rooms and storage areas get two Loop Zero devices, which measure temperature and humidity. Refrigerators and freezers get two Loop Extemp devices, with the probe inside the appliance and the device outside it. The number of devices and their places are settled in the temperature mapping, and two devices at the same measuring point prepare for a device failure.
- Own battery, connection and memory. Each device has its own battery, its own 4G connection and its own memory, so the failure of one device does not interrupt the measurement of the space.
- Not dependent on one operator. The device is not tied to a single operator: it uses the networks of all operators, so its coverage does not depend on one operator's network. If the connection still breaks, the device stores the measurements in its memory and sends them to the service when the connection returns. Storing requires that the device stays on.
- Alongside the current system. The devices are not connected to the site's network. That is why they can work alongside a monitoring system already in use, as a second, independent measurement.
- Alarms on the device's status too. Alarms can be received by email and text message when a limit is exceeded or undercut for the set delay. An alarm is also sent when a device stops sending data and when its battery charge falls below 10%.
- Data in your own system too. The measurement data is stored in a service located in the EU. Through the API, the distributor can transfer the data to its own system and keep it there according to its own procedures.
What can be shown to the authorities
Each space has its measurement history, from which you can get a PDF report and a CSV file for a chosen period. The service also has a history of alarm events. Measurement data is not removed from the service without the customer's separate request, and calibrating a device does not change measurements already stored.
Measurement as part of the distributor's quality system
The requirements of the guidelines are directed at the distributor's quality system. The distributor, for example, carries out the temperature mapping, validates the systems it uses and decides how often alarms are tested and devices calibrated. The measuring devices and the service produce the continuous measurement data, alarms and reports that the distributor uses in these procedures.